Section07410-MetalRoofandWallPanels_第1頁(yè)
Section07410-MetalRoofandWallPanels_第2頁(yè)
Section07410-MetalRoofandWallPanels_第3頁(yè)
Section07410-MetalRoofandWallPanels_第4頁(yè)
Section07410-MetalRoofandWallPanels_第5頁(yè)
已閱讀5頁(yè),還剩3頁(yè)未讀, 繼續(xù)免費(fèi)閱讀

下載本文檔

版權(quán)說(shuō)明:本文檔由用戶提供并上傳,收益歸屬內(nèi)容提供方,若內(nèi)容存在侵權(quán),請(qǐng)進(jìn)行舉報(bào)或認(rèn)領(lǐng)

文檔簡(jiǎn)介

1、FloIinsARCHITECTUIiAL SVSTEMSs LLCSECTION 07410METAL ROOF AND WALL PANELSDisplay hidden notes to specifier. (Don't know how? Click Here )PART 1 GENERAL1.1 SECTION INCLUDESA. Curved metal wall panels.B. Curved metal roof panels.C. Straight metal wall panels.D. Straight metal roof panels.E. Metal

2、soffit panels.1.2 RELATED SECTIONSA. Section 05120 - Structural Steel: Tolerances for primary and secondary building structure supporting framework.B. Section 05300 - Structural Metal Roof and Floor Decking: Roof decking material and installation.C. Section 05400 - Structural Steel Stud Framing: Ext

3、erior wall framing.D. Section 06100 - Rough Carpentry: Blocking and miscellaneous framing.E. Section 06125 - Wood Decking: Wood deck material and installation.F. Section 07210 - Building Insulation: Rigid insulation at insulated walls and roof decks.G. Section 07620 -Sheet MetalFlashing and Trim: In

4、stallationrequirements.H. Section 07710 -Gutters andDownspouts: Roof edge coordinationandattachmentprovisions.I. Section 07900 -Joint Sealants: Installation requirements.1.3 REFERENCESA. Building DesignCodes:1. Basic Building Code (BBC), Building Officials and Code Administrators, International (BOC

5、A).2. International Conference of Building Officials (ICBO), Uniform Building Code (UBC).07410-13. National Building Code (NBC), National Conference of States on Building Codes and Standards, Inc.4. The Southern Standard Building Code (SBCC).B. American Iron and Steel Institute (AISI) - North Americ

6、an Specification for the Design of Cold-Formed Steel Structural Members.C. American Institute of Steel Construction (AISC) Manual of Steel Construction.D. ASTM A 446 - Specification for Steel Sheet, Zinc-Coated (Galvanized) by theHot-Dip Process, Structural (Physical) Quality (Withdrawn 1994.Replace

7、 withASTM A653 / A653M - 08 Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process).E. ASTM A525 - Specification for General Requirements for Steel Sheet, Zinc-Coated (Galvanized) by the Hot-Dip Process (Withdrawn 1994. Replac

8、ed with ASTM A653 Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process).F. ASTM A653 - Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process.G. ASTM

9、A 792:Standard Specification for Steel Sheet, Aluminum-Zinc Alloy Coated(Galvalume or Acrylume) by the Hot Dip ProcessH. ASTM B 209:Standard Specification for Steel Sheet, Aluminum and AluminumAlloy Sheet and Plate.I. Metal Building Manufacturers Association (MBMA) - Metal Roofing Systems Design Man

10、ual.1.4 PERFORMANCE REQUIREMENTS FOR ROOF SYSTEMSA. Design Requirements:1. The metal roof system shall be designed by the manufacturer as a complete system. All components of the system shall be supplied by the same manufacturer.2. Roof Panels: Steel panels shall be designed in accordance with the A

11、ISI Cold-Formed Steel Design Manual.3. Deflection requirements shall be in accordance with the applicable building code, or as a minimum, L/180 for roof snow load (but not less than 20 psf (98 kg/sq m).4. Accessories and Fasteners: Accessories and fasteners shall be capable of resisting the specifie

12、d design wind uplift forces and shall allow for thermal movement of the roof panel system. Exposed fasteners shall not restrict free movement of the roof panel system resulting from thermal forces, except at designed points of roof panel fixity.5. Design Loads: Design load application shall be in ac

13、cordance with local building code.6. Dead Loads: The dead load shall be the weight of the metal roof system.a. Collateral Loads shall not be applied to the roof panels.7. Live Loads: The panels and fasteners shall be capable of supporting a minimum uniform live load of 20 psf (98 kg/sq m).8. Snow Lo

14、ads: The design ground snow loads shall be as defined on the Contract Documents.9. Wind Loads: The design wind loads shall be based on the wind criteria defined in the Contact Documents.07410-210. Thermal Effects: Roof panels shall be free to move in response to the expansion and contraction forces

15、resulting from temperature variation, as specified in the MBMA Metal Roofing Systems Design Manual.11. Rainfall Intensity: Exterior gutters and downspouts shall be designed for rainfall intensity based upon a 5-year recurrence interval for a five minute duration. Interior gutters, valleys and downsp

16、outs shall be designed for rainfall intensity based upon a 25-year recurrence interval based on a five minute duration.1.5 PERFORMANCE REQUIREMENTS FOR WALL SYSTEMSA. Design Requirements for Wall Systems:1. System Design: Metal wall system shall be designed by the manufacturer as a complete system.

17、All components of the system shall be supplied by the same manufacturer.2. Wall Panels: Steel panels shall be designed in accordance with the AISI Cold-Formed Steel Design Manual.3. Design Loads: Design load application shall be in accordance with local building code.4. Wind Loads: The design wind l

18、oads shall be based on the wind criteria defined in the Contract Documents.5. Deflection: Deflection requirements shall be in accordance with the applicable building code, or as a minimum, L/180 for wind load (but not less than 10 psf (49 kg/sq m).6. Accessories and Fasteners: Accessories and fasten

19、ers shall be capable of resisting the specified design wind suction forces.B. Framing Members Supporting the Metal Panel System:1. Any additions/revisions to framing members supporting the metal panel system to accommodate the manufacturer/fabricator's design shall be the Contractor's respon

20、sibility, and shall be submitted for review and approval by the Engineer of Record.2. Framing members and their connections shall be designed in accordance with AISC, AISI, and LGSI design specifications as applicable. Deflection requirements shall be in accordance with the applicable building code,

21、 or as a minimum, the provisions of the AISC Steel Design Guide Series 3 - Serviceability Design Considerations for Low-Rise-Buildings.1.6 SUBMITTALSA. Submit under provisions of Section 01300.B. Product Data: Manufacturer's data sheets on each product to be used, including preparation recommend

22、ations, storage and handling requirements, and installation methods.C. Shop Drawings: Submit shop Drawings showing methods of installation, elevations and plans of roof and wall panels, sections and details, specified loads, flashings, roof curbs, vents, sealants, interfaces with all materials not s

23、upplied by the metal panel system manufacturer, and proposed identification of component parts and their finishes. Do not proceed with fabrication prior to approval of shop Drawings.D. Selection Samples:1. Submit samples and color chips for all proposed finishes.2. Submit two 3 inch by 5 inch (76 mm

24、 by 127 mm) color chip samples ofavailable colors for selection07410-31.7 QUALITY ASSURANCEA. Manufacturer Qualifications: Manufacturer shall have a minimum of fifteen years experience in manufacturing metal roof and wall systems.1. Panels specified in this section shall be produced in a permanent f

25、actory environment with fixed-base roll-forming equipment. Roll forming of the profiled panels, curving of all panels, factory mitering of corners, and fabricating of all curved flashings shall be performed by the manufacturer.2. Manufacturer shall submit names and addresses of five previous project

26、s of equal size and scope.3. Specified system shall have been in use in the United States for a minimum of ten years.B. Installer Qualifications: Installer shall have completed five projects of similar scope and magnitude that have been in service for a minimum of five years with satisfactory perfor

27、mance of the panel system. Installer's foreman shall be trained in the proper installation of the specified system, and present at all times when material is being installed.1. Installer shall submit names and addresses of five previous projects of equal size and scope.C. Regulatory Requirements

28、: Comply with specified performance and local building code requirements. In the event of conflict, comply with the higher performing or more restrictive requirement.1.8 DELIVERY, STORAGE, AND HANDLINGA. Inspect materials for damage upon arrival at job site.B. Store products in manufacturer's un

29、opened packaging until ready for installation.C. Store all material and accessories in clean, dry area out of direct contact with theground, under cover, out of sunlight to prevent U.V. damage to any protective film, and sloped for drainage. Provide proper ventilation of metal panel system to preven

30、t condensation build-up between each panel or trim/flashing component.D. Protect material from damage.E. Protect material from contamination by corrosive or staining agents.1.9 PROJECT CONDITIONSA. Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended b

31、y manufacturer for optimum results.Do not install productsunder environmental conditions outside manufacturer's absolute limits.1.10 WARRANTYA. Finish Warranty: Manufacturer warrants that under normal outdoor atmospheric conditions the roof and wall panels will meet the following requirements:1.

32、 Fluorocarbon (PVDF):a. The paint film will not crack, flake, chip or peel for a period of 20 years.b. The paint will not chalk in excess of number 8 rating for a period of 20years.c. The paint will not fade in excess of 5 NBS Units for a period of 20 years.PART 2 PRODUCTS07410-42.1 MANUFACTURERSA.

33、Acceptable Manufacturer: Floline Architectural Systems, LLC, 25523Ruff Street,Plainfield, Illinois 60585. ASD Telephone: (630) 922-7879. Fax (630) 922-0880.Web: .B. Substitutions: Not permitted.C. Requests for substitutions will be considered in accordance with provisions of Section 01600.2.2 MATERI

34、ALSA. Galvanized Steel: Zinc coated hot dipped G-90 galvanized steel, minimum spangle, extra smooth, Grade 33 min (33 KSI yield) conforming to ASTM A653 and ASTM A525.B. Galvalume Steel: Aluminum-zinc coated steel conforming to ASTM A792 SQ Grade 50B with AZ50 or AZ55 coating.C. Aluminum: 3003-H14 A

35、lloy or equivalent conforming to ASTM B209.D. Stainless Steel: Type 304 steel conforming to ASTM A240.2.3 SYSTEMSA. Application:Curved wall panels.B. Application:Curved wall roof panels.C. Application:Straight wall panels.D. Application:Straight roof panels.E. Application:Soffit panels.F. Profile: P

36、rovide the following profile:1. Floline 900: 1-1/2 inch (38 mm) deep with ribs spaced 5.9 inches (150 mm) on center; nominal cover width of 35.4 inches (900 mm); side lap occurs at top of high ribs.2. Floline 900R: 1-1/2 inch (38 mm) deep with ribs spaced 5.9 inches (150 mm) on center; nominal cover

37、 width of 35.4 inches (900 mm); side lap occurs in valley of the low rib.3. Floline 940: 1-1/2 inch (38 mm) deep with ribs spaced 7.2 inches (183 mm) on center; nominal cover width of 36 inches (914 mm); side lap occurs at top of high rib.4. Floline 940R: 1-1/2 inch (38 mm) deep with ribs spaced 7.2

38、 inches (183 mm) on center; nominal cover width of 36 inches (914 mm); side lap occurs in valley of the low rib.5. Floline 990: 1-1/2 inch (38 mm) deep with ribs spaced 11.8 inches (300 mm) on center; nominal cover width of 35.4 inches (900 mm); side lap occurs at top of high ribs.6. Floline 990R: 1

39、-1/2 inch (38 mm) deep with ribs spaced 11.8 inches (300 mm) on center; nominal cover width of 35.4 inches (900 mm); side lap occurs in valley of the low rib.G. Minimum Thickness:1. 24 gauge.07410-52. 22gauge.3. 20gauge.4. 18gauge.H. Curved Panels: Form to configuration and radii as indicated on the

40、 Drawings.I. Mitered Corners: Fabricate as follows:1. Straight mitered.2. Curved mitered.3. As indicated on Drawings.J. Finish: Full Strength Kynar 500?/Hylar 5000 (contains a minimum 70% Kynar/Hylar polyvinylidene fluoride (PVDF) resins) premium flouropolymer coating system of 1.0 (±0.1) mil t

41、otal dry film thickness. For additional protection a wash coat of 0.3 -0.4 mil dry film thickness is applied to the reverse side.1. Color:Dark Bronze2. Color:Extra Dark Bronze3. Color:Mansard Brown4. Color:Medium Bronze5. Color:Matte Black6. Color:Charcoal Gray7. Color:Cityscape.8. Color:Slate Gray9

42、. Color:Stone White10. Color:Bone White11. Color:Almond12. Color:Sierra Tan13. Color:Sandstone14. Color:Tropical Patina15. Color:Sherwood Green16. Color:Hartford Green17. Color:Hemlock Green18. Color:Patina Green19. Color:Dark Ivy20. Color:Teal21. Color:Regal Blue22. Color:Electric Blue23. Color:Awa

43、rd Blue24. Color:Sky Blue25. Color:Brandywine26. Color:Regal Red27. Color:Colonial Red28. Color:Terra Cotta29. Color:Silver Metallic30. Color:Classic Copper31. Color: Champagne Metallic32. Color: Custom:2.4 ACCESSORIESA. Metal Components:1. Provide accessories and other items essential to completene

44、ss of roof installation including trim, flashing, fascia, metal closure strips, caps, gutters, downspouts, roof curbs, column covers, soffits and similar metal component.2. Form components from same gauge and finish as metal panels, unless otherwise noted.07410-6B. Flashing:1. C urved Flashing: Fact

45、ory curve and fabricate in smooth arc and in one continuous piece, where possible. Exposed side edges shall be hemmed. Flashing ends shall be butt jointed with concealed splice plates.a. Cut and tucked or segmented and overlapped flashing is not acceptable.2. Metal Closures: Shall be of same materia

46、l, gauge, finish and color as panels.C. Fasteners:1. Exposed fasteners shall be hex head self-drilling screws with bonded washers and color finished to match panels. Screws may be either plated carbon steel or stainless steel as noted on the drawings.2. Concealed Fasteners: Zinc-coated steel or stai

47、nless steel.3. Exposed rivets shall match color finish of panel.D. Closure Strips: Closed-cell or solid-cell synthetic EPDM rubber or polyethylene pre-molded to match configuration of the covering and shall not absorb or retain water.E. Sealants:1. Exposed Sealants: Shall be one component polyuretha

48、ne based as recommended by panel manufacturer: field applied.2. Concealed Sealants: Non-curing, non-skinning butyl, polyisobutylene or polybutane tape as recommended by panel manufacturer; field applied.2.5 FABRICATIONA. Form and fabricate components of the system to the profiles, patterns, and drai

49、nage arrangements as determined by Architect, with minimal oil canning or panel distortion.1. Fabricate exposed items of prefinished sheet metal, color to match panels.B. Unless otherwise shown on Drawings or specified herein, panels shall be full length. Fabricate flashings and accessories in longest practical lengths.C. Metal panels shall be factory formed on a stationary industrial type rolling mill. Field formed panels are not acceptable.D. Panel Orientation: Panels with metallic finish are directional and shall be oriented so as to produce a consistent visual effe

溫馨提示

  • 1. 本站所有資源如無(wú)特殊說(shuō)明,都需要本地電腦安裝OFFICE2007和PDF閱讀器。圖紙軟件為CAD,CAXA,PROE,UG,SolidWorks等.壓縮文件請(qǐng)下載最新的WinRAR軟件解壓。
  • 2. 本站的文檔不包含任何第三方提供的附件圖紙等,如果需要附件,請(qǐng)聯(lián)系上傳者。文件的所有權(quán)益歸上傳用戶所有。
  • 3. 本站RAR壓縮包中若帶圖紙,網(wǎng)頁(yè)內(nèi)容里面會(huì)有圖紙預(yù)覽,若沒有圖紙預(yù)覽就沒有圖紙。
  • 4. 未經(jīng)權(quán)益所有人同意不得將文件中的內(nèi)容挪作商業(yè)或盈利用途。
  • 5. 人人文庫(kù)網(wǎng)僅提供信息存儲(chǔ)空間,僅對(duì)用戶上傳內(nèi)容的表現(xiàn)方式做保護(hù)處理,對(duì)用戶上傳分享的文檔內(nèi)容本身不做任何修改或編輯,并不能對(duì)任何下載內(nèi)容負(fù)責(zé)。
  • 6. 下載文件中如有侵權(quán)或不適當(dāng)內(nèi)容,請(qǐng)與我們聯(lián)系,我們立即糾正。
  • 7. 本站不保證下載資源的準(zhǔn)確性、安全性和完整性, 同時(shí)也不承擔(dān)用戶因使用這些下載資源對(duì)自己和他人造成任何形式的傷害或損失。

最新文檔

評(píng)論

0/150

提交評(píng)論